View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000886 | OpenFOAM | Bug | public | 2013-06-12 08:22 | 2013-06-12 11:44 |
Reporter | nogenmyr | Assigned To | henry | ||
Priority | normal | Severity | feature | Reproducibility | N/A |
Status | resolved | Resolution | fixed | ||
Summary | 0000886: sampling time format... | ||||
Description | Thanks for nice fix of the engineTime restart issues (871). A related issue is the output time when sampling with probes. There, time will always be written in seconds, independent of user's time. A similar fix as in report 871 can be used for probes: lines 79 & 103 in sampling/probes/probesTemplates.C probeStream << setw(w) << Field.time().timeToUserTime(vField.time().value()); and similar in: lines 46 & 70 in sampling/probes/patchProbesTemplates.C | ||||
Tags | No tags attached. | ||||