Summary | 0003225: results are quite different | ||||
Description | Hello, I ran the same tutorial case: nozzleflow2d which is located in $FOAM_TUTORIALS/multiphase/interfoam/les/nozzleflow2d with openfoam 5.0 and openfoam 6.0, respectively. However, I got quite different results, as shown below. I think that the results from openfoam 5.0 are more reasonable to me. Does anybody know the reason? Thanks. Hua Ji | ||||
Tags | No tags attached. | ||||
|
|
|
The difference is due to the change in ddtPhiCorrCoeff which was required for some cases running with a VERY small Courant number. However other cases have responded badly to this change and it has been reverted in OpenFOAM-dev pending further testing and development. To obtain results more similar to those from 5.x upgrade to OpenFOAM-dev. |
Date Modified | Username | Field | Change |
---|---|---|---|
2019-04-21 10:54 | hua ji | New Issue | |
2019-04-21 10:54 | hua ji | File Added: nozzleflow2d_openfoam_5_0.png | |
2019-04-21 10:54 | hua ji | File Added: nozzleflow2d_openfoam_6_0.png | |
2019-04-21 11:15 | henry | Priority | urgent => low |
2019-04-21 11:15 | henry | Severity | major => minor |
2019-04-21 11:15 | henry | Description Updated | |
2019-04-21 13:28 | henry | Assigned To | => henry |
2019-04-21 13:28 | henry | Status | new => closed |
2019-04-21 13:28 | henry | Resolution | open => fixed |
2019-04-21 13:28 | henry | Fixed in Version | => dev |
2019-04-21 13:28 | henry | Note Added: 0010436 |