View Issue Details

IDProjectCategoryView StatusLast Update
0002675OpenFOAMBugpublic2017-08-29 16:50
Reporterroth Assigned Tohenry  
PrioritynormalSeverityminorReproducibilityalways
Status resolvedResolutionfixed 
PlatformGNU/LinuxOSUbuntuOS Version16.04
Product Versiondev 
Summary0002675: limitTemperature does not limit temperatures on boundary patches
DescriptionApplying the limitTemperature fvOptions constraint does not effectively limit the temperature on the boundary patches.
Steps To ReproduceAttached case is derived from buoyantRadiationRoomFvDOM but
1) turned off radiation
2) set to run for 100 steps and write every 10
3) changed box that was fixed T=600 to a fixed heat flux of 100 using externalWallHeatFluxTemperature
4) added a fvOptions file to limit temperature between 200 & 350K
5) added a writeObject for rho

Temperature on box patch well exceeds 350K.
TagsfvOptions

Activities

roth

2017-08-23 17:38

reporter  

henry

2017-08-29 16:50

manager   ~0008647

Resolved in OpenFOAM-5.x by commit 437961d24742738136253cb47d98e93266373a59

Resolved in OpenFOAM-dev by commit bebb8ecb1ffd0be0f07fe2af693410acdc3d7ef8

Issue History

Date Modified Username Field Change
2017-08-23 17:38 roth New Issue
2017-08-23 17:38 roth File Added: buoyantFoamLimitTemp.tar.gz
2017-08-23 17:38 roth Tag Attached: fvOptions
2017-08-29 16:50 henry Assigned To => henry
2017-08-29 16:50 henry Status new => resolved
2017-08-29 16:50 henry Resolution open => fixed
2017-08-29 16:50 henry Note Added: 0008647