View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000945 | OpenFOAM | Bug | public | 2013-08-06 12:34 | 2013-08-09 13:11 |
Reporter | dkxls | Assigned To | |||
Priority | normal | Severity | minor | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Platform | OpenSUSE 12.2 | OS | Linux | OS Version | x86_64 |
Summary | 0000945: [ReactingParcel]: Set Tvap to min. triple point temperature of the components and do NOT read it from the dictionary | ||||
Description | Tvap should be set to the minimum triple point temperatures of the components in a parcel. It is unnecessary (and error prone) to make the user specify this quantity in the spray dictionary. Hence, remove the lookup of this quantity from the dictionary. | ||||
Additional Information | src/lagrangian/intermediate/parcels/Templates/ReactingParcel/ReactingParcelI.H | ||||
Tags | Evaporation, Lagrangian, spray, sprayEngineFoam, sprayFoam | ||||
|
After re-considerations that I laid out in bug #942 I think Tvap should be set to the (pseudo) triple point temperature Tpt(X). An implementation of Tpt(X) is given also in bug #942. http://www.openfoam.org/mantisbt/view.php?id=942 |
|
Thanks for the report - fixed by commit 54ce53 |
Date Modified | Username | Field | Change |
---|---|---|---|
2013-08-06 12:34 | dkxls | New Issue | |
2013-08-06 17:48 | dkxls | Note Added: 0002376 | |
2013-08-07 12:35 | dkxls | Tag Attached: Evaporation | |
2013-08-07 12:35 | dkxls | Tag Attached: Lagrangian | |
2013-08-07 12:35 | dkxls | Tag Attached: spray | |
2013-08-07 12:35 | dkxls | Tag Attached: sprayEngineFoam | |
2013-08-07 12:35 | dkxls | Tag Attached: sprayFoam | |
2013-08-09 13:11 |
|
Note Added: 0002383 | |
2013-08-09 13:11 |
|
Status | new => resolved |
2013-08-09 13:11 |
|
Fixed in Version | => 2.2.x |
2013-08-09 13:11 |
|
Resolution | open => fixed |
2013-08-09 13:11 |
|
Assigned To | => user2 |