View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000941 | OpenFOAM | Bug | public | 2013-08-05 09:18 | 2013-08-05 13:45 |
Reporter | Assigned To | ||||
Priority | low | Severity | trivial | Reproducibility | N/A |
Status | resolved | Resolution | fixed | ||
Summary | 0000941: Typo in description of turbulentIntensityKineticEnergyInletFvPatchScalarField | ||||
Description | In the description of turbulentIntensityKineticEnergyInletFvPatchScalarField it is stated that k is calculated from k = 1.5*I*U^2. The correct equation should be k = 1.5*(I*U)^2, which is also how it is actually implemented. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2013-08-05 09:18 |
|
New Issue | |
2013-08-05 13:45 |
|
Note Added: 0002367 | |
2013-08-05 13:45 |
|
Status | new => resolved |
2013-08-05 13:45 |
|
Fixed in Version | => 2.2.x |
2013-08-05 13:45 |
|
Resolution | open => fixed |
2013-08-05 13:45 |
|
Assigned To | => user2 |