Summary0000811: P1 radiation model uses old style .snGrad()
DescriptionThe P1.C uses the old style .snGrad() in line 247 without checking for being a wall patches before.
The simulation will crash when being run in parallel.
Steps To ReproduceRun tutorial heatTransfer/buoyantSimpleFoam/hotRadiationRoom with P1 model and buoyantSimpleFoam in parallel. The solver will crash immediately.
TagsNo tags attached.

Activities

henry

2013-04-09 11:02

manager   ~0002102

Resolved by commit 8ca6a09672e32fb079b9eff587e81a8fe13d5a60

Issue History

Date Modified Username Field Change
2013-04-08 18:45 martinB New Issue
2013-04-09 11:02 henry Note Added: 0002102
2013-04-09 11:02 henry Status new => resolved
2013-04-09 11:02 henry Resolution open => fixed