View Issue Details

IDProjectCategoryView StatusLast Update
0002641OpenFOAMBugpublic2017-07-28 15:46
Reportergdtech Assigned Tohenry  
PrioritynormalSeveritymajorReproducibilityalways
Status closedResolutionfixed 
PlatformGNU/LinuxOSCentos OS Version7
Summary0002641: Flow in a straight tube does not remain uniform at outlet with buoyantSimpleFoam
DescriptionThe flow in a straight tube without obstacle does not remain uniform as expected.

This behavior is reduced when constant/g is reduced or if the size of the domain is smaller.
Steps To Reproducetar -xf tube.tgz
buoyantSimpleFoam
TagsNo tags attached.

Activities

gdtech

2017-07-28 14:32

reporter  

tube.tgz (140,487 bytes)

gdtech

2017-07-28 14:33

reporter  

velocity.png (65,569 bytes)   
velocity.png (65,569 bytes)   

gdtech

2017-07-28 14:33

reporter  

p_rgh.png (41,865 bytes)   
p_rgh.png (41,865 bytes)   

henry

2017-07-28 15:46

manager   ~0008475

User support request.

Issue History

Date Modified Username Field Change
2017-07-28 14:32 gdtech New Issue
2017-07-28 14:32 gdtech File Added: tube.tgz
2017-07-28 14:33 gdtech File Added: velocity.png
2017-07-28 14:33 gdtech File Added: p_rgh.png
2017-07-28 15:46 henry Assigned To => henry
2017-07-28 15:46 henry Status new => closed
2017-07-28 15:46 henry Resolution open => fixed
2017-07-28 15:46 henry Note Added: 0008475